Groundwater Monitoring Instrumentation Product Diver-Office Network Groundwater data management software to program and read Diver dataloggers.
Dedicated desktop solution for programming multiple groundwater Diver dataloggers, downloading measurements onto your PC, and exporting data to a spreadsheet or modeling program.
Click here to download Diver-Office or click on below "Get Quote" button.
Diver-VisiONE* comprehensive groundwater monitoring software is an intuitive desktop application designed for public water agencies, environmental consultants, and industries to effectively manage their groundwater monitoring and reporting requirements. Read more
Program multiple groundwater Diver dataloggers; download Diver datalogger measurements onto your PC, and export data to a spreadsheet or modeling program. Diver-Office Network is a flexible “project-based” measurement software package designed for exchanging critical Diver information. Download Diver-Office Network (License is required to run the Diver-Office Network)
In addition to the Diver-Office functionality, Diver-Office Network allows you to:
Share the database on a network
Have multiple people simultaneously accessing the database
Backup and restore your database
Drag-and-drop time series between different monitoring points
Search for (part of a) monitoring point name
Select a manual measurement to be used for the barometric compensation
The Perfect Companion
From the field to your office, Diver-Office Network is an important part of Diver-NETZ. Integrating first-class technologies with the industry’s latest wireless communication and data management capabilities, Diver-NETZ dramatically improves data collection in the field - up to 70% more efficient than traditional methods. Click here to find out more.
Easy-to-use, Intuitive Interface
Diver-Office Network enables you to easily:
Read/Program Diver dataloggers
Start/Stop Diver dataloggers, with various start methods
Calibrate CTD-Divers
Import/Export monitoring data in multiple formats
View time series data in a plot or tabular form
Import LoggerDataManager (LDM) 5.x databases
Perform barometric compensation on water level data
Quick Reading and Programming of Diver Settings
You can read all settings from a Diver with one click.
Setting Description
Diver Type
Diver Status (started or stopped)
Serial Number
Memory Left
Battery Left
Firmware Version
Pressure Range
Conductivity Range
Location
Sampling Method
Sampling Interval
Altitude (if applicable)
Once the settings have been read, you can easily modify and program essential Diver settings.
Location
Sample Method (Fixed, Event Based, predefined pumping test settings, or User Defined)
Sample Interval
Altitude (if applicable)
Conductivity Range (if applicable)
On-the-Fly Calibration of CTD-Divers
Regular CTD-Diver calibration is highly recommended for accurately measuring conductivity. Retrieve calibration history with a push of a button or easily calibrate your ceramic CTD-Divers by simply placing the CTD-Diver in a standard (lab) calibration solution.
Effortless Barometric Compensation
All Diver dataloggers measure groundwater level with a highly accurate absolute pressure sensor. Diver-Office Network can quickly subtract atmospheric pressure measurements obtained with Baro-Divers to accurately compensate for air pressure variations. Baro-Diver data can be downloaded and easily assigned to any location for barometric compensation. Water levels can be compensated and expressed in the following three ways:
The height of the water column above the Diver
With respect to the top of well casing (ToC)
With respect to a vertical reference datum
What's New in 2009.1
The following new features are available in Diver-Office Network 2009.1:
Enhanced Location Tree
Added ability to expand/collapse all tree nodes by right-clicking the root of the location tree.
Location names are now automatically listed in alphabetical order.
A new location is automatically added to the tree when a new Diver is started, allowing you to enter manual measurements while the Diver is deployed in the field.
Data Export
Exported data files can now be accessed directly from the Diver-Office Network interface by selecting the "View Files" (located in the Export dialog that appears after the files have been successfully exported).
Plot Settings
The y-axis range on time series plots can now be modified by manually entering user defined minimum and maximum values in the plot settings.
CTD-Diver Calibration
Diver-Office Network now allows you to restore CTD-Divers to the original factory settings.
Set the Project Time
A new project setting allows you to specify the time convention (e.g. Daylight Savings time, Standard Time, or System Time) on which your Divers operate. This feature helps ensure that your data is always aligned to a standard time when the time shifts due to daylight savings.
What's New in 2008
The following new features are available in Diver-Office Network 2008:
Internationalization
In addition to English and Dutch, Diver-Office Network now supports the following languages: Spanish, Portuguese, German and French
Import Data from Diver-Pocket and Diver-Mate
Data from field devices such as Diver-Pocket and Diver-Mate can now be imported directly into your Diver-Office Network project
Added Averaging Sampling Method
Program your Divers (Cera-Diver and Micro-Diver only) to store an averaged value of measurements for each parameter, over a user-specified averaging interval
Basic QA/QC Data Filter
All downloaded and imported data is now automatically passed through a basic QA/QC filter to check for erroneous and corrupted data, and for maximum and minimum values on all Diver channels
Save Diver Settings
Diver Settings are now retained in the Diver-Office Network project tree for each location in your project, allowing you to access Diver settings while the Diver is deployed in the field
Time Series Graph Enhancements
Several enhancements have been made to the time series plotting component. Improvements include: ability to copy plot to clipboard, save the plot as an *.EMF and *.WMF graphics file, view Diver parameters on multiple y-axis, view time series records in the table by selecting a point on the graph
Calculated Cable Length
Diver-Office Network automatically calculates a cable length when barometric compensation is performed using a manual measurement. This calculated cable length can then be used in subsequent barometric compensation operations when data is collected via wireless connection, e.g., with Diver-Pocket, when manual measurements are rarely taken
Actual Data
Actual data now displays the current date and time of the connected Diver. For Micro-Diver, Cera-Diver, Mini-Diver and CTD-Diver (ceramic only), you can now retrieve real time measurements for each parameter when Actual Data is refreshed, even when the Diver is not started
General Improvements
Added "Cancel" button in Diver dialog allowing you to stop downloading when data is being retrieved from Divers
Diver dialog now displays the date and time at which a Diver starts and stops
The default project folder is now located in My Documents, allowing you quicker access to exported data files
Diver-Office Network is a dedicated desktop solution that enables you to program multiple Diver dataloggers, download measurements onto your PC, and export data to a spreadsheet or modeling program. Diver dataloggers have multiple applications including:
DAT - A binary format exported with every Diver download MON - An ASCII file format supported by SWS software CSV - Comma Separated Values format, compatible with Microsoft Excel NITG - A standard database format in The Netherlands
Smart Future Start (SFS)
The SFS option is a useful tool in situations where you want to stop the Diver, download its data, and then continue collecting data at the specified sample interval. This option allows you to download data in contiguous segments, while maintaining a consistent sample interval.
Sample Method and Sample Interval
Choose from fixed, event-based, one of the predefined pumping test settings, or user defined sample methods.
Fixed -The Diver takes and stores samples in regular time intervals
Event Based –The Diver compares each sample to the last stored sample and calculates a difference
Predefined Pumping Tests - Diver-Office Network includes three convenient predefined pumping tests for Divers that support this feature, e.g., TD-Diver, Cera-Diver and Micro-Diver
User Defined Pumping Tests (Cera-Diver and Micro-Diver only) - If none of the predefined pumping tests are suitable, you can define and select your own customized pumping test sampling method
Altitude
For TD- and CTD-Divers only, you can enter a value for the altitude above sea level of the location of the Diver within the range of - 300 m to 3,000 m (-984 ft to 9,842 ft)
Conductivity Range
For CTD-Diver DI-263, two additional fields will appear in the Location settings when the Diver settings are read. For the Conductivity Range, choose between 80.00 or 30.00 mS/cm.
System Requirements
Pentium processor, 800 MHz
256 MB of RAM
100 MB available hard drive space for installation. Additional space for database is required. Diver-Office Network supports databases up to 300 MB
One available USB port or one Serial COM port
Windows 2000 (SP4), Windows XP (SP2 or later, 32 & 64-bit), Windows Vista Business (32 & 64-bit)
Screen resolution: 1024 x 768, color: 16 bits)
Microsoft SQL Server 2005 Compact Edition (Included in installation package)
Communication with Diver-Pocket
ActiveSync 4.5 for Windows XP or earlier - allows Diver-Office Network to communicate with Diver-Pocket on your portable device.
Schlumberger Water Services offers innovative groundwater monitoring solutions plus software for data management, data analysis, visualization, and modeling with a complete range of educational training and support services for environmental consultants, government agencies, industry, and educational/research institutions.