You are here:Dataloggers»Groundwater Monitoring Software»Diver-Office

Diver-Office

Diver-Office
  • Free.
  • Easy to use.
  • Tested on Windows 7 (32 and 64 bit).
  • Groundwater data management software for programming and reading Diver dataloggers.
  • Easily convert your Diver data into water levels.
  • Visualize your data on time series plots.

Program, download data, compensate and export datalogger data

Program Divers and download Diver measurements onto your PC. Export the data to a spreadsheet or modeling program. Diver-Office is a flexible “project-based” measurement software package designed for exchanging Diver data. Diver-Office is easy-to-use and has an intuitive user interface.

  • Start/Stop/Read/Program Divers
  • Calibrate CTD-Divers
  • Barometric compensation
  • Export monitoring data to CSV (Excel)
  • Units: metric - imperial
  • 7 languages: Chinese - Dutch - English - French - German - Portuguese - Spanish

Contents


What's new in Diver-Office 2011.1

  • Improved graphing (save settings per monitoring point, apply settings to all existing graphs, set settings as default, better zooming)
  • Real time graph (for pump tests)
  • Compatible with Windows 7
  • Allow entering negative values for cable length
  • Check for updates option
  • User feedback option

Features

Reading and programming of Diver settings

You can read all settings from a Diver. Once the settings have been read, you can modify and program the Diver settings.
  • Monitoring Point
  • Sample Method (Fixed, Event Based, predefined pumping test settings, or User Defined)
  • Sample Interval
  • Conductivity Range (if applicable)
  • Calibration of CTD-Divers

Regular CTD-Diver calibration is recommended for accurately measuring conductivity. Retrieve calibration history with a push of a button or calibrate your CTD-Divers using the calibration wizard and standard laboratory calibration solutions.

Barometric Compensation

All Divers measure pressure with an absolute pressure sensor. Diver-Office can quickly subtract atmospheric pressure measurements obtained with Baro-Divers to compensate for air pressure variations. Water levels can be expressed in the following three ways:

  • The height of the water column above the Diver
  • With respect to the top of casing
  • With respect to a vertical reference datum

You only have to setup your project once. The next time you downloaded new Diver data just start the barometric compensation wizard and let Diver-Office calculate your water levels.

Supported Devices

Reading Units
  • Reading Unit RS232 AS315
  • Reading Unit USB AS327
  • Diver USB Reading Unit AS330
Diver Dataloggers
  • Cera-Diver DI701 DI702 DI705 DI710
  • Mini-Diver DI500 DI501 DI502 DI505 DI510
  • Micro-Diver DI601 DI602 DI605 DI610
  • (M)TD-Diver DI240 DI241 DI243 DI245
  • Baro-Diver DI250 DI500
  • CTD-Diver (ceramic) DI261 DI263 DI265 DI271 DI272 DI273
  • CTD-Diver (stainless steel) DI218 DI219 DI221 DI223 DI224
  • TD-Diver DI212 DI213 DI214 DI215 DI217 DI220
Interface Cables
  • Direct Read Interface Cable AS 325
  • PC Interface Boostercable AS 326
  • DRC USB Interface Cable AS 327
  • Direct Read Interface (short) AS 328
  • FT-US232B EVALCABLE HAD 211

Export Formats

  • DAT – A binary format exported with every Diver download
  • MON – An ASCII file format supported by SWS software
  • CSV – Comma Separated Values format, compatible with Microsoft Excel
  • NITG – A standard database format in The Netherlands

Smart future start (SFS)

The SFS option is a useful tool in situations where you want to stop the Diver, download its data, and then continue collecting data at the specified sample interval. This option allows you to download data in continuous segments, while maintaining a consistent sample interval and reducing download time.

Sample method and sample interval

  • Fixed – The Diver takes and stores samples in regular time intervals
  • Event Based – The Diver compares each sample to the last stored sample and only stores the new sample if a user defined threshold is exceeded
  • Predefined Pumping Tests – Diver-Office includes three convenient predefined pumping tests for Divers that support this feature, e.g., TD-Diver, Cera-Diver and Micro-Diver
  • User Defined Pumping Tests (Cera-Diver, Micro-Diver, and CTD-Diver DI27x only) – If none of the predefined pumping tests are suitable, you can define and select your own customized pumping test sampling method
  • Averaging (Cera-Diver, Micro-Diver, and CTD-Diver DI27x only) – The Diver takes a user defined number of samples and stores the average value

Altitude

For selected TD- and CTD-Divers (older) models only. You can enter a value for the altitude above sea level of the location of the Diver within the range of -300 m to 3,000 m (-984 ft to 9,842 ft).

Note: Current Diver models automatically adjust for altitude ranging from -300 m to 5,000 m (-984 ft to 16,404 ft).

Conductivity Range

For the ceramic CTD-Divers two additional fields will appear in the monitoring point settings when the Diver settings are read. For the Conductivity Range, choose conductivity range and the type of conductivity: true or specific (conductivity at 25 °C). Depending on the type of ceramic CTD-Diver the following conductivity ranges are available:

  • DI26x: 30.00 or 80.00 mS/cm
  • DI27x: 30.00 or 120.00 mS/cm

Database

  • Diver-Office supports databases up to 4 GB
  • Diver-Office uses a Microsoft SQL Server database or Microsoft SQL CE database

System Requirements

Supported Operating Systems

  • Windows XP (SP2 or later, 32 & 64-bit)
  • Windows Vista Business (32 & 64-bit)
  • Windows 7 Professional (32 & 64-bit)

Note: Windows XP Home, Windows Vista/Windows 7 Home Premium, Home Basic or Starter Versions are not supported.

Hardware

  • Processor: Pentium 4-compatible processor or higher, 1.6 GHz or higher recommended.
  • Hard Disk: 2GB (3GB or more recommended)
  • Memory: 1GB RAM (2GB or more recommended)
  • Serial communication: One available USB port or one Serial COM port
  • Screen resolution: 1024 x 768, color: 16 bits
  • Microsoft SQL Server Compact Edition 3.5 SP2 (included in installation package)
  • Communication with Diver-Pocket - allow Diver-Office to import data from Diver-Pocket:
    • ActiveSync 4.5 for Windows XP or earlier
    • Windows Mobile Device Center 6.1 for Windows Vista or Windows 7

Downloads

Application

Manuals and Quick Reference Guides

USB Reading Unit drivers

The USB Reading Unit and USB Interface Cable driver are automatically installed when Diver-Office is installed. In case you want to re-install them you can download them here.


Frequently Asked Questions

Diver-Office FAQ